This course (SCT-DVSNAM1A) is for engineering and maintenance personnel responsible for installing, maintaining and troubleshooting drive systems that use the SINAMICS S (S110, S120, S150) drive systems.
2.6 CEUs (Continuing Education Credits)
PRICE: $3,750.00
SUGGESTED PREREQUISITE: 20 AC Motor Basics & 24 AC Drive Basics
This course is intended to provide knowledge and skills related to the SINAMICS S drive as it pertains to commissioning, operation, configuration, maintenance, diagnostics, and troubleshooting. It is formatted as a combination of instruction and carefully structured, hands-on exercises aimed at developing job-related knowledge and skills.
Objectives
Upon completion of this course, the student shall be able to:
- Locate modules, terminals, options, and features on the SINAMICS S series drives.
- Create an offline project in SINAMICS STARTER
- Connect with the Drive via STARTER
- Commission the Drive with STARTER for Servo Motors
- Take local control of a drive using the STARTER Control Panel
- Configure Analog, Digital, and Comm. I/O
- Configure, Trace, and Evaluate BICO connections in the drive control logic
- Use Device Trace to monitor signals
- Use STARTER tools to troubleshoot and correct Topology errors
- Perform required Drive optimizations - servo
- Commission the Drive with STARTER for Induction Motors
- Perform required Drive optimizations - vector
- Configure the Setpoint channel
- Evaluate and configure operating states, alarms and fault codes
- Activate and Configure the Basic Positioner
- Set the Basic Positioner Home Position
- Traverse the axis with a traversing program
- Configure and test S7 communications between an S7 PLC CPU and S120 Drive via PROFIBUS
Topics
- S120 Fundamentals and Overview
a. Frequency Converter principles
b. S120 Components
- SINAMICS STARTER
a. Overview
b. Project Creation
c. Project Structure
- S120 Control Units and Additional System Components
- STARTER connection to target device
a. PG/PC Interface
- Line and Motor Modules
- Control Word, Setpoint, and Device Trace
a. Required Enables
b. Control and Status Words
c. Input and Output Terminals
d. BICO Technology
e. Device Trace
- S120 Topology
a. Drive-Cliq
- Chassis and Cabinet Power Units
- Closed Loop Control - servo
a. Operating modes
b. Speed, Current, and Torque control
c. Optimization - automatic
d. Optimization - manual
- Closed Loop Control - vector
a. Induction motor design
b. Commissioning an induction motor
c. Optimizing and induction motor control
- Setpoint Channel
- Diagnostics
a. LEDs
b. Fault and Alarm memories
c. Comparison features in STARTER
- Basic Positioner
a. Overview
b. Activating and Configuring the Basic Positioner
- S120 Communication
a. Overview
b. PROFIDRIVE
c. Telegram configuration
d. Device and S7 Online Access Points
- Further Drive Functions
a. Line Contactor Control
b. Brake Control
c. Flying Restart
d. Vdc Controller
e. Simulation Mode
f. Technology Controller
g. Drive Control Chart